Alpha Fire Protection Limited - IFC Certifiede
Alpha Fire Protection Limited - VCR Certifiede
IAPFP - Irish Association for Passive Fire Protection member
Alpha Fire Protection Limited - ASFP Certifiede

Fire Rated Shaft Wall: Kemwell Corex A1 Systems

Shaft walls enclose lift shafts, stair cores and service risers.

Discuss your projectCall +353 1 961 0087

Shaft walls enclose lift shafts, stair cores and service risers. They are often built from one side only, close to the programme's critical path, and they form part of the building's life safety system. Alpha Fire Protection Ltd installs Kemwell Corex A1 shaft wall systems throughout Ireland, across a range of sectors including offices, residential, healthcare, education and commercial buildings.

Our installers specialise in high-spec fire-rated upgrades and details. Every shaft wall is built to Kemwell's tested details and fixing centres, and recorded in Bolster.

For the wider Kemwell board range, see fire resistant boards. For service enclosures and fire-rated ductwork, see fire-rated enclosures.

What a Shaft Wall Has to Do

A shaft wall has to keep fire and smoke in the shaft, or out of it, for the period required by the fire safety strategy, from either side. It also has to accept service penetrations, access panels and head details without losing that performance. The fire resistance belongs to the complete tested system: boards, studs, tracks, screws and centres, not to the board on its own.

Kemwell Corex A1 Shaft Wall

The Kemwell Corex A1 shaft wall uses two layers of A1 Corex on a steel stud frame, with no mineral wool required. A1 Corex is classified A1 to EN 13501-1 and H1 to EN 15283-1, and can be installed before the building is weathertight. The shaft wall is classified to the Efectis classification report as follows:

Fire resistance (both sides) Boards Frame
EI 60 2 x 15 mm A1 Corex DU 75 track (38 x 75 x 38 mm, 0.5 mm), DC 75 studs (47 x 74 x 47 mm, 0.6 mm) at 600 mm centres
EI 90 2 x 20 mm A1 Corex DU 75 track, DC 75 studs at 600 mm centres
EI 120 2 x 25 mm A1 Corex DU 75 track, DC 75 studs at 600 mm centres

The data sheet gives each wall without width restriction, up to 4 m high.

Kemwell shaft wall with vertical cable trays, installed by Alpha Kemwell shaft wall with vertical cable trays, installed by Alpha Kemwell shaft wall with vertical cable trays, installed by Alpha
Kemwell shaft wall with vertical cable trays, installed by Alpha

Fixing Centres per the Manufacturer's Testing

These are the centres in the Kemwell Corex A1 shaft wall data sheet. They are the details an inspector or fire engineer will check, and they are recorded in Bolster as we build.

  • Tracks: DU 75 track fixed at a maximum of 500 mm centres, using M6 x 45 mm steel or masonry anchors
  • Studs: DC 75 studs at 600 mm centres
  • First-layer boards: self-tapping corrosion-resistant screws 3.5 x 38 mm at 400 mm centres
  • Second-layer boards:
    • EI 60: 3.5 x 45 mm screws at 300 mm centres
    • EI 90: 3.5 x 55 mm screws at 300 mm centres
    • EI 120: 4.8 x 70 mm screws at 300 mm centres
  • Outer-layer joints are taped with fibreglass tape and filled; outer-layer fasteners are filled as normal

We do not substitute studs, tracks, screw types or centres. Where a shaft is taller than the 4 m height given on the data sheet, or the detail falls outside the tested scope, we raise it with the design team and Kemwell for a tested solution.

Penetrations, Access and Firestopping

Every service that passes through a shaft wall breaks the compartment unless it is sealed to a tested detail. Because Alpha also installs the firestopping, we coordinate the wall, the openings and the seals as one package:

  • mixed services sealed with Nullifire FB750 fire batt
  • plastic pipes fitted with tested collars and wraps
  • head and deflection joints sealed with tested sealants

See our fire stopping services.

Recorded in Bolster

Each shaft wall run is located on the drawings in the Bolster Systems app, photographed as it is built, and QR-tagged at penetrations and agreed details. That gives the main contractor, fire engineer and assigned certifier a traceable record of the system, the fixing centres and the seals, for handover and later maintenance. Read more on how we work.

Why Alpha Fire Protection

  • Kemwell Corex A1 shaft wall, firestopping and surveys from one specialist contractor
  • Installers specialising in high-spec fire-rated upgrades, building to the manufacturer's tested fixing centres
  • Members of the IFC, ASFP, VCR and CIF. See our accreditation page.
  • We work nationwide, mainly in Dublin, Meath, Louth, Kildare, Wicklow, Cavan and Monaghan

Get a Shaft Wall Quotation

Send us your riser and shaft drawings and fire strategy and we will propose a tested Kemwell Corex A1 system. Call +353 1 961 0087, email info@alphafireprotection.ie, or contact us.

Registered office: 60 Merrion Square South, Dublin 2, D02 HE24

Frequently Asked Questions

What is a fire-rated shaft wall?

A fire-rated shaft wall is a tested partition that encloses a lift shaft, stair core or service riser and keeps its integrity and insulation for a stated period, from either side, as part of the building's life safety system.

What fire resistance does a Kemwell Corex A1 shaft wall achieve?

EI 60 with 2 x 15 mm A1 Corex, EI 90 with 2 x 20 mm, and EI 120 with 2 x 25 mm, from both sides, on DC 75 studs at 600 mm centres, up to 4 m high, according to the Kemwell data sheet and the Efectis classification report.

Do you need mineral wool in a Corex A1 shaft wall?

No. The Kemwell Corex A1 shaft wall data sheet states that no mineral wool is required.

What fixing centres are used?

Tracks are fixed at a maximum of 500 mm centres. Studs are at 600 mm centres. First-layer screws are at 400 mm centres and second-layer screws at 300 mm centres, with screw type and length as tested for the fire resistance period.

Can services pass through a shaft wall?

Yes, but each penetration must be sealed with a tested firestopping detail for that wall type. Alpha installs the wall and the seals together and records both in Bolster.

Do you also install fire-rated enclosures and ductwork?

Yes. See fire-rated enclosures for FireKem FP-900 service enclosures and fire-rated ductwork.

Get in touch

Registered Office
60 Merrion Square South
Dublin 2, D02 HE24
Secure Your Property’s Safety Today!
Take the first step towards unparalleled safety with our expert fire protection services.

© 2026 Alpha Fire Protection Limited. All rights reserved