Alpha Fire Protection Limited - IFC Certifiede
Alpha Fire Protection Limited - VCR Certifiede
IAPFP - Irish Association for Passive Fire Protection member
Alpha Fire Protection Limited - ASFP Certifiede

Fire-Rated Enclosures and FireKem FP-900 Ductwork

Mechanical and electrical services that pass through more than one compartment have to be protected so that fire and smoke cannot travel with them.

Discuss your projectCall +353 1 961 0087

Mechanical and electrical services that pass through more than one compartment have to be protected so that fire and smoke cannot travel with them. Alpha Fire Protection Ltd installs Kemwell FireKem FP-900 fire-rated service enclosures and fire-rated ductwork throughout Ireland, across a range of sectors including offices, healthcare, education, commercial and industrial buildings.

Fire-rated enclosures and ducts are part of the building's life safety system. Our installers specialise in high-spec fire-rated upgrades and details. We build every system to Kemwell's tested details and fixing centres, and record it in Bolster.

For general board systems and steel encasement, see fire resistant boards. For risers and lift shafts, see shaft wall.

FireKem FP-900 Board

FireKem FP-900 is a non-combustible, autoclaved calcium silicate fire protection board, classified Euroclass A1 to EN 13501-1. Kemwell systems using FP-900 are tested for up to 240 minutes (BS 476 Parts 20 to 24 and BS EN 1364-1 and 2). Kemwell describes the board as dimensionally stable under elevated temperatures and in severe moisture environments.

Typical board size is 1200 x 2400 mm. See the FireKem FP-900 product page.

Building Services Enclosures

FireKem FP-900 service enclosures protect cables, pipes and ducts so that fire is contained for the period required by the fire strategy. The Kemwell building services brochure describes enclosures that provide fire resistance of up to 240 minutes integrity and insulation, or up to 240 minutes integrity, when exposed to fire from the outside or the inside, depending on the tested construction.

Four-sided enclosures are the standard arrangement. Penetrations by the enclosure through walls and floor slabs must be sealed to a tested detail so the compartment line is not broken. We coordinate the enclosure and those seals as one package.

Fire rated box enclosure built by Alpha, frame stage Fire rated box enclosure built by Alpha, boarding in progress Fire rated box enclosure built by Alpha, finished
Fire rated box enclosure built by Alpha
Ductwork rising through a stairwell before the fire rated riser enclosure is built Steel frame of a fire rated riser enclosure with stone wool insulation fitted Boarded fire rated riser enclosure with red QR installation tags
Fire rated riser enclosure built by Alpha: services, frame with stone wool insulation, then boarded with red QR installation tags
Fire rated cable tray enclosure built by Alpha Fire rated beam enclosure built by Alpha
Fire rated cable tray enclosure and beam enclosure, built by Alpha

Fire-Rated Ductwork

Alpha also installs FireKem FP-900 fire-rated ventilation, smoke extract and kitchen extract ductwork. Kemwell FireKem FP-900 duct systems have been tested to BS 476: Part 24: 1987 (ISO 6944-1985) and demonstrated fire resistance of up to 240 minutes. The Kemwell fire-rated ductwork data sheet states that the systems provide:

  • 60, 120, 180 or 240 minutes in terms of the stability and integrity criteria of BS 476 Part 24
  • 0, 30, 60, 120, 180 or 240 minutes in terms of the insulation criterion, depending on the construction
  • fire attack from either outside the duct (Duct A) or inside the duct (Duct B)

A full appraisal of duct systems for various applications has been issued by Exova Warringtonfire UK. One cited approval on the data sheet is Exova 336212-2, with an FRL of up to 240/240/240.

Where a construction is shown on the data sheet, we follow it. For example, one illustrated ventilation duct detail uses M4 self-tapping screws at 200 mm centres and M8 metal anchor bolts at 400 mm centres. Screw type, centres and collar sizes vary with the fire rating and the duct arrangement, so we take the centres from the tested detail for that system, not from a generic rule.

Ceiling-level fire rated duct enclosure frame with stone wool insulation Ceiling-level fire rated duct enclosure, boarded
Fire rated duct enclosure built by Alpha: frame with stone wool insulation, then boarded

Installed to Tested Details

On every enclosure or duct installation we check:

  • the board thickness, layers and framing against the tested system for the required period
  • fixing centres per the manufacturer's testing for that detail
  • support, hangers and clearance as specified
  • tight joints, corners and junctions, with no gaps at walls, floors or steel
  • every service penetration and wall or floor intersection sealed to a tested firestopping detail

Where site conditions fall outside the tested scope, we raise it with the design team and Kemwell. We do not improvise.

Recorded in Bolster

Each enclosure and duct run is located on the drawings in the Bolster Systems app, photographed as it is built, and QR-tagged at agreed locations and penetrations. That record sits in the handover pack and can be checked after later services works. Read more on how we work.

Fire Rated Ceilings

We also build fire rated ceilings: stone wool insulation fitted to the ceiling grid, then boarded and QR-tagged in Bolster.

Stone wool insulation fitted to a fire rated ceiling grid Stone wool insulation in a fire rated ceiling with QR tags Corridor fire rated ceiling being boarded over stone wool insulation
Finished boarded fire rated ceiling with red QR installation tags
Fire rated ceiling built by Alpha: stone wool insulation, then boarded and QR-tagged

Why Alpha Fire Protection

  • FireKem FP-900 enclosures and ductwork, shaft wall, firestopping and surveys from one specialist contractor
  • Installers specialising in high-spec fire-rated upgrades, building to the manufacturer's tested fixing centres
  • Members of the IFC, ASFP, VCR and CIF. See our accreditation page.
  • We work nationwide, mainly in Dublin, Meath, Louth, Kildare, Wicklow, Cavan and Monaghan

Get an Enclosures Quotation

Send us your services drawings and fire strategy and we will propose a tested FireKem FP-900 system. Call +353 1 961 0087, email info@alphafireprotection.ie, or contact us.

Registered office: 60 Merrion Square South, Dublin 2, D02 HE24

Frequently Asked Questions

What is a fire-rated service enclosure?

A fire-rated service enclosure is a tested board system built around electrical or mechanical services so that fire and smoke cannot travel with those services between compartments, for a stated period of integrity and, where required, insulation.

What board do you use for enclosures and fire-rated ductwork?

Kemwell FireKem FP-900, an A1 non-combustible calcium silicate fire protection board. Kemwell systems using FP-900 are tested for up to 240 minutes, depending on the application.

Are fire-rated ducts tested from the inside as well as the outside?

Yes. Kemwell FireKem FP-900 duct systems are tested to BS 476 Part 24 for fire attack from outside the duct (Duct A) and from inside the duct (Duct B).

Do you install kitchen extract and smoke extract ductwork?

Yes. FireKem FP-900 systems cover ventilation, smoke extract and kitchen extract ducts, selected to the tested construction for the period required by the fire strategy.

How are the boards fixed?

To the fixing centres in the manufacturer's tested detail for that system. One illustrated ventilation duct detail, for example, uses M4 self-tapping screws at 200 mm centres and M8 metal anchor bolts at 400 mm centres. We do not use generic centres.

Is every enclosure recorded?

Yes. Each run is photographed, located on the drawings and QR-tagged in the Bolster Systems app.

Get in touch

Registered Office
60 Merrion Square South
Dublin 2, D02 HE24
Secure Your Property’s Safety Today!
Take the first step towards unparalleled safety with our expert fire protection services.

© 2026 Alpha Fire Protection Limited. All rights reserved