Alpha Fire Protection Ltd is a specialist passive fire protection contractor with a dedicated team based in Dublin and the surrounding counties. We install, survey and record fire stopping and compartmentation systems for main contractors, fire engineers and facilities managers across the city, working on a mixture of projects from city-centre commercial offices and mixed-use developments to data centres, warehouses, industrial plants and hospitality buildings.
Passive fire protection is a life safety system. Every compartment wall, fire-rated floor and protected shaft is designed to hold back fire and smoke for a defined period, giving occupants time to escape and the fire service time to respond. Each unsealed penetration, open joint or missing cavity barrier undermines that design. Our job is to make sure the fire-resisting construction shown on the fire safety strategy still performs as tested once services, partitions and facades are in place.
We deliver the full passive fire protection package from one specialist contractor, so interfaces between trades are detailed and recorded by the same team.
Sealing of pipes, cables, cable trays, ductwork and mixed services where they pass through fire-resisting walls and floors, together with linear joint and wall-head seals. See our firestopping service for the full technical scope.
Fire barriers in ceiling voids, roof spaces and raised floors, and cavity barriers in external wall and curtain walling construction. See fire barrier systems and cavity barriers and curtain walling.
Kemwell fire-rated board, encasements and shaft wall systems for risers, lift shafts and protected routes. More on our Kemwell partnership.
Intumescent coatings and board encasement to structural steelwork, with dry film thickness verification. See fire protecting structural steelwork and DFT testing.
Fire door inspection and installation, fire damper testing and inspection, and passive fire surveys of existing compartmentation.
Dublin's building stock ranges from Georgian and Victorian buildings converted for modern use, to post-war office blocks undergoing deep retrofit, to high-density new-build commercial and residential schemes. Each brings its own compartmentation risks:
Technical Guidance Document B sets out how buildings are divided into fire compartments. Correctly installed fire stopping is what keeps those compartments intact in use. It also supports the inspection and documentation regime that main contractors, assigned certifiers and building owners rely on at completion.
Alpha uses Nullifire for all firestopping work. Products are selected from the manufacturer's tested details for each substrate, service and gap. They include:
Every system is installed to the manufacturer's tested details, with fixing centres as per manufacturer's testing. That covers seal depth, annular space, service support distances and substrate thickness. Where a site condition falls outside the tested scope, we raise it with the design team and the manufacturer rather than improvise a detail.
For board and shaft wall, we use Kemwell, including Corex A1 board, the Corex A1 Shaftwall system and FireKem fire-rated partitions. Our installers specialise in high-spec fire-rated upgrades and details: shaft walls, riser encasements, lift shaft openings and the junctions where board systems meet firestopping. These interfaces are where compartmentation most often fails. Having one specialist team responsible for both the board and the seal removes that gap.
Alpha uses the Bolster Systems passive fire app to survey, install and record all fire stopping. Each penetration is pinned on the layout drawing, photographed and tagged with a coded Bolster QR label on site. The record holds the location, product used and system reference. Clients can view progress in real time from any device.
At handover, the Bolster record gives the main contractor, fire engineer and building owner a traceable, photo-backed inventory of every seal for the O&M file. Facilities managers can then use it to track the impact of later maintenance works on compartment integrity. See how we work.
Alpha Fire Protection is a member of the Irish Association for Passive Fire Protection (IAPFP), the Irish body promoting best practice, training and education in passive fire protection. In Dublin, our team constructed the training walls at the IAPFP training centre. The installation includes a Kemwell shaft wall system, a self-supporting shaft wall ceiling, a glazed leaf-and-a-half fire door and multiple service penetrations used to train the next generation of installers.
Our accreditation page also lists IFC third-party certification, ASFP membership, VCR registration and CIF membership.
Our Dublin work covers a mixture of projects from city-centre offices, residential and mixed-use schemes to technology, logistics and industrial facilities:
Recent Dublin projects include Coopers Cross, The Exo Building, Spencer Dock and 2 Windmill Lane.
Compartmentation degrades over a building's life as services are added and altered. We carry out passive fire surveys with numbered, photographed findings and marked-up drawings, then complete remedial fire stopping to tested details. We also offer a fire safety maintenance plan for ongoing inspections.
The team is based in Dublin and works throughout Ireland, Northern Ireland and the UK. That includes firestopping in Cork and firestopping in Limerick. The full list of our services is here.
Send us your drawings, fire strategy or survey findings and we will come back with a technical proposal based on tested Nullifire and Kemwell systems. Call 01 961 0087, email info@alphafireprotection.ie, or contact us for a quotation.
Registered office: 60 Merrion Square South, Dublin 2, D02 HE24
A passive fire protection contractor installs and maintains the built-in elements that contain fire and smoke within compartments. These include fire stopping, fire and cavity barriers, fire-rated board and shaft walls, structural steel protection and fire doors. Together they form a life safety system that protects escape routes and limits fire spread.
Fire stopping seals gaps and service penetrations through fire-resisting walls and floors to maintain the compartment's fire resistance. Cavity barriers close concealed spaces, such as wall cavities, ceiling voids and curtain walling, to stop fire and smoke spreading unseen. Most Dublin projects need both.
We use Nullifire for all firestopping, including FB750 Intubatt, FS702, FS703 and FS709 sealants, FR230 Intucompound, and FP-range collars, wraps and sleeves. For fire-rated board and shaft wall, we use Kemwell. Everything is installed to the manufacturer's tested details, with fixing centres as per manufacturer's testing.
Every penetration is recorded in the Bolster Systems app and tagged on site with a Bolster QR label. The record includes photographs, location, product and system reference. The result is a traceable record for the O&M manual that facilities managers can keep using after handover.
Yes. We regularly start with a passive fire survey that numbers and photographs each defect against the drawings, then carry out remedial fire stopping to tested details. Working hours and access in occupied buildings are agreed with the client.
Yes. Alpha Fire Protection is a member of the Irish Association for Passive Fire Protection (IAPFP), and our team built the training walls at the IAPFP training centre in Dublin.